Fanuc 0/00/0-mate Control Alarms

0 - PLEASE TURN OFF POWER
1 - TH PARITY ALARM
2 - TV PARITY ALARM
3 - TOO MANY DIGITS
4 - ADDRESS NOT FOUND
5 - NO DATA AFTER ADDRESS
6 - ILLEGAL USE OF NEGATIVE SIGN
7 - ILLEGAL USE OF DECIMAL POINT
8 - ILLEGAL USE OF PROGRAM END
9 - ILLEGAL ADDRESS INPUT
10 - IMPROPER G-CODE
11 - NO FEEDRATE COMMANDED/
14 - CAN NOT COMMAND G95 / ILLEGAL LEAD COMMAND
15 - TOO MANY AXES COMMANDED
20 - OVER TOLERANCE OF RADIUS
21 - ILLEGAL PLANE AXIS COMMANDED
22 - NO CIRCLE RADIUS
23 - ILLEGAL RADIUS COMMAND
25 - CANNOT COMMAND F0 IN G02/G03 (M series)
27 - NO AXES COMMANDED IN G43/G44 (M series)
28 - ILLEGAL PLANE SELECT
29 - ILLEGAL OFFSET VALUE
30 - ILLEGAL OFFSET NUMBER
31 - ILLEGAL P COMMAND IN G10
32 - ILLEGAL OFFSET VALUE IN G10
33 - NO SOLUTION AT CRC
34 - NO CIRC ALLOWED IN ST-UP /EXT
35 - CAN NOT COMMANDED G39 / G31
36 - CAN NOT COMMANDED G31
37 - CAN NOT CHANGE PLANE IN CRC / CAN NOT CHANGE PLANE IN NRC
38 - INTERFERENCE IN CIRCULAR BLOCK
39 - CHF/CNR NOT ALLOWED IN NRC
40 - INTERFERENCE IN G90/G94 BLOCK
41 - INTERFERENCE IN CRC /NRC
42 - G45/G48 NOT ALLOWED IN CRC
43 - ILLEGAL T-CODE COMMAND
44 - G27-G30 NOT ALLOWED IN FIXED CYC
45 - ADDRESS Q NOT FOUND (G73/G83)
46 - ILLEGAL REFERENCE RETURN COMMAND
47 - ILLEGAL AXIS SELECT
48 - BASIC 3 AXIS NOT FOUND
49 - ILLEGAL OPERATION (G68/G69)(M series)
50 - CHF/CNR NOT ALLOWED IN THRD
51 - MISSING MOVE AFTER CHF/CNR
52 - CODE IS NOT G01 AFTER CHF/CNR
53 - TOO MANY ADDRESS COMMANDS
54 - NO TAPER ALLOWED AFTER CHF/ CNR (T series)
55 - MISSING MOVE VALUE IN CHF/CNR
56 - NO END POINT & ANGLE IN CHF/CNR
57 - NO SOLUTION OF BLOCK END
58 - END POINT NOT FOUND
59 - PROGRAM NUMBER NOT FOUND
60 - SEQUENCE NUMBER NOT FOUND
61 - ADDRESS P/Q NOT FOUND IN G70-G73 (T series)
62 - ILLEGAL COMMAND IN G71-G76 (T series)
63 - SEQUENCE NUMBER NOT FOUND
64 - SHAPE PROGRAM NOT MONOTONOUSLY
65 - ILLEGAL COMMAND IN G71-G73 (T series)
66 - IMPROPER G-CODE IN G71-G73
67 - CAN NOT ERROR IN MDI MODE
69 - FORMAT ERROR IN G70-G73
70 - NO PROGRAM SPACE IN MEMORY
71 - DATA NOT FOUND
72 - TOO MANY PROGRAMS
73 - PROGRAM NUMBER ALREADY IN USE
74 - ILLEGAL PROGRAM NUMBER
75 - PROTECT
76 - ADDRESS P NOT DEFINED
77 - SUB PROGRAM NESTING ERROR
78 - NUMBER NOT FOUND
79 - PROGRAM VERIFY ERROR
80 - G37ARRIVALSIGNALNOT ASSERTED
81 - OFFSET NUMBER NOT FOUND IN G37
82 - H-CODE NOT ALLOWED IN G37 / T-CODE NOT ALLOWED IN G37
83 - ILLEGAL AXIS COMMAND IN G37
85 - COMMUNICATION ERROR
86 - DR SIGNAL OFF
87 - BUFFER OVERFLOW
90 - REFERENCE RETURN INCOMPLETE
91 - REFERENCE RETURN INCOMPLETE or MANUAL RETURN TO THE REFERENCEPOSITION IS IMPOSSIBLEBECAUSE OF A TEMPORARYSTOP.
92 - AXES NOT ON THE REFERENCE POINT
94 - P TYPE NOT ALLOWED (COORD CHG)
95 - P TYPE NOT ALLOWED (EXT OFS CHG)
96 - P TYPE NOT ALLOWED (WRK OFS CHG)
97 - P TYPE NOT ALLOWED (AUTO EXEC)
98 - G28 FOUND IN SEQUENCE RETURN
99 - MDI EXEC NOT ALLOWED AFT. SEARCH
100 - PARAMETER WRITE ENABLE
101 - PLEASE CLEAR MEMORY
110 - DATA OVERFLOW
111 - CALCULATED DATA OVERFLOW
112 - DIVIDED BY ZERO
113 - IMPROPER COMMAND
114 - FORMAT ERROR IN MACRO
115 - ILLEGAL VARIABLE NUMBER
116 - WRITE PROTECTED VARIABLE
118 - PARENTHESIS NESTING ERROR
119 - ILLEGAL ARGUMENT
122 - FOUR FOLD MACRO MODAL-CALL or DUPLICATE MACRO MODAL-CALL
123 - CAN NOT USE MACRO COMMAND IN DNC
124 - MISSING END STATEMENT
125 - FORMAT ERROR IN MACRO
126 - ILLEGAL LOOP NUMBER
127 - NC, MACRO STATEMENT IN SAME BLOCK
128 - ILLEGAL MACRO SEQUENCE NUMBER
129 - ILLEGAL ARGUMENT ADDRESS
130 - ILLEGAL AXIS OPERATION
131 - TOO MANY EXTERNAL ALARM MESSAGES
132 - ALARM NUMBER NOT FOUND
133 - ILLEGAL DATA IN EXT. ALARM MSG
135 - ILLEGAL ANGLE COMMAND / SPINDLE ORIENTATION PLEASE
136 - ILLEGAL AXIS COMMAND / C/H-CODE IN SAME BLK.
137 - M-CODE & MOVE CMD IN SAME BLK.
139 - CAN NOT CHANGE PMC CONTROL AXIS
140 - BP/S alarm
141 - CAN NOT COMMAND G51 IN CRC
142 - ILLEGAL SCALE RATE
144 - ILLEGAL PLANE SELECTED
146 - IMPROPER G CODE
148 - ILLEGAL SETTING DATA
150 - ILLEGAL TOOL GROUP NUMBER
151 - TOOL GROUP NUMBER NOT FOUND
152 - NO SPACE FOR TOOL ENTRY
153 - T-CODE NOT FOUND
154 - NOT USING TOOL IN LIFE GROUP
155 - ILLEGAL T-CODE IN M06
156 - P/L COMMAND NOT FOUND
157 - TOO MANY TOOL GROUPS
158 - ILLEGAL TOOL LIFE DATA
159 - TOOL DATA SETTING INCOMPLETE
160 - MISMATCH WAITING M-CODE / G72.1 NESTING ERROR
161 - G72.1 NESTING ERROR
163 - COMMAND G68/G69 INDEPENDENTLY T series (At two-path)
169 - ILLEGAL TOOL GEOMETRY DATA
175 - ILLEGAL G107 COMMAND
176 - IMPROPER G CODE IN G107
177 - CHECK SUM ERROR (G05 MODE)
178 - G05 COMMANDED IN G41/G42 MODE
179 - PARAM. (NO. 7510) SETTING ERROR
180 - COMMUNICATION ERROR (REMOTE BUF)
181 - FORMAT ERROR IN G81 BLOCK (Hobbing machine, EGB) (M series)
182 - G81 NOT COMMANDED
183 - DUPLICATE G83
184 - ILLEGAL COMMAND IN G81
185 - RETURN TO REFERENCE POINT
186 - PARAMETER SETTING ERROR
190 - ILLEGAL AXIS SELECT
194 - SPINDLE COMMAND IN SYNCHRO-MODE
195 - SPINDLE CONTROL MODESWITCH
197 - C-AXIS COMMANDED IN SPINDLE MODE
199 - MACRO WORD UNDEFINED
200 - ILLEGAL S CODE COMMAND
201 - FEEDRATE NOT FOUND IN RIGID TAP
202 - POSITION LSI OVERFLOW
203 - PROGRAM MISS AT RIGID TAPPING
204 - ILLEGAL AXIS OPERATION
205 - RIGID MODE DI SIGNAL OFF
206 - CAN NOT CHANGE PLANE
207 - RIGID DATA MISMATCH
210 - CAN NOT COMMAND M198/M199
211 - G31 (HIGH) NOT ALLOWED IN G99 or CAN NOT COMMAND HIGH-SPEEDSKIP
212 - ILLEGAL PLANE SELECT
213 - ILLEGAL COMMAND IN SYNCHRO-MODE
214 - ILLEGAL COMMAND IN SYNCHRO-MODE
217 - DUPLICATE G51.2 (COMMANDS)
218 - NOT FOUND P/Q COMMAND IN G251
219 - COMMAND G250/G251 INDEPENDENTLY
220 - ILLEGAL COMMAND IN SYNCHR-MODE
221 - ILLEGAL COMMAND IN SYNCHR-MODE
222 - DNC OP. NOT ALLOWED IN BG.-EDIT
224 - RETURN TO REFERENCE POINT
225 - SYNCHRONOUS/MIXED CONTROL ERROR T series
226 - ILLEGAL COMMAND IN SYNCHRO-MODE T series
229 - CAN NOT KEEP SYNCHRO-STATE
230 - R CODE NOT FOUND
231 - ILLEGAL FORMAT IN G10 OR L50
232 - TOO MANY HELICAL AXIS COMMANDS
233 - DEVICE BUSY or P/S ALARM
239 - BP/S ALARM
240 - BP/S ALARM
241 - ILLEGAL FORMAT IN G02.2/G03.2
242 - ILLEGAL COMMAND IN G02.2/G03.2
243 - OVER TOLERANCE OF END POINT
244 - P/S ALARM
245 - T-CODE NOT ALLOWED IN THIS BLOCK
246 - No message
247 - No message
250 - Z AXIS WRONG COMMAND (ATC) / SIMULTANEOUS M06 AND Z-AXISMOVEMENT NOT ALLOWED
251 - ATC ERROR
252 - ATC SPINDLE ALARM
253 - G05 IS NOT AVAILABLE
300 - n-axis origin return
301 - APC alarm: nth-axis communication
302 - APC alarm: nth-axis over time
303 - APC alarm: nth-axis framing
304 - APC alarm: nth-axis parity
305 - APC alarm: nth-axis pulse error
306 - APC alarm: nth-axis battery voltage 0
307 - APC alarm: nth-axis battery low 1
308 - APC alarm: nth-axis battery low 2
309 - APC ALARM: n AXIS ZRN IMPOSSIBL
310/320/330/340/350/360/370/380 - n-axis origin return
311/321/331/341/351/361/371/381 - APC alarm: nth-axis communication
312/322/332/342/352/362/372/382 - APC alarm: nth-axis over time
313/323/333/343/353/363/373/383 - APC alarm: nth-axis framing
314/324/334/344/354/364/374/384 - APC alarm: nth-axis parity
315/325/335/345/355/365/375/385 - APC alarm: nth-axis pulse error
316/326/336/346/356/366/376/386 - APC alarm: nth-axis battery voltage 0
317/327/337/347/357/367/377/387 - APC alarm: nth-axis battery low 1
318/328/338/348/358/368/378/388 - APC alarm: nth-axis battery low 2
319/329/339/349/359/369/379/389 - SPC ALARM: n AXIS PULSE CODER
400 - SERVO ALARM: 1, 2TH AXIS OVERLOAD
401 - SERVO ALARM: 1, 2TH AXIS VRDY OFF
402 - SERVO ALARM: 3, 4TH AXIS OVERLOAD
403 - SERVO ALARM: 3, 4TH AXIS VRDY OFF
404 - SERVO ALARM: n-th AXIS VRDY ON
405 - SERVO ALARM: ZERO POINT RETURN FAULT
406 - SERVO ALARM: 7, 8TH AXIS OVER LOAD or 7, 8TH AXIS VRDY OFF
409 - SPINDLE ALARM DETECTION
410,420,430,440,450,460,470 - SERVO ALARM: n-th AXIS - EXCESS ERROR
411,421,431,441,451,461,471 - SERVO ALARM: n-th AXIS - EXCESS ERROR
413,423,433,443,453,463,473 - SERVO ALARM: n-th AXIS - LSI OVERFLOW
414,424,434,444,454,464,474 - SERVO ALARM: n-th AXIS - DETECTION RELATED ERROR
415,425,435,445,455,465,475 - SERVO ALARM: n-th AXIS - EXCESS SHIFT
416,426,436,446,456,466,476 - SERVO ALARM: n-th AXIS - DISCONNECTION
417,427,437,447,457,467,477 - SERVO ALARM: n-th AXIS - PARAMETER INCORRECT
490 - SERVO ALARM: 5TH AXIS OVER LOAD
491 - SERVO ALARM: 5, 6TH VRDY OFF
494 - SERVO ALARM: 5, 6TH AXIS VRDY ON
495 - SERVO ALARM: 5, 6TH AXIS ZEROPOINT RETURN
408 - SPINDLE SERIAL LINK STARTFAULT
5n0 - OVER TRAVEL : +n
5n1 - OVER TRAVEL : -n
5n2 - OVER TRAVEL : +n
5n3 - OVER TRAVEL : -n
5n4 - OVER TRAVEL : +n
5n5 - OVER TRAVEL : -n
5n4 - OVER TRAVEL : +n
5n5 - OVER TRAVEL : -n
520 - OVER TRAVEL : +Z
590 - Tool post interference alarm:+X-axis
591 - Tool post interference alarm:-X-axis
592 - Tool post interference alarm:+Z-axis
593 - Tool post interference alarm:-Z-axis
500-599 - Macro alarms
600 - PMC ALARM : INVALID INSTRUCTION
601 - PMC ALARM : RAM PARITY
602 - PMC ALARM : SERIAL TRANSFER
603 - PMC ALARM : WATCHDOG
604 - PMC ALARM : ROM PARITY
605 - PMC ALARM : OVER STEP
606 - PMC ALARM : I/O MODULE ASSIGNMENT
607 - PMC ALARM : I/O LINK
700 - OVERHEAT: CONTROL UNIT
704 - OVERHEAT: SPINDLE
899 - M-NET INTERFACE ALARM
910 - MAIN RAM PARITY / DRAM PARITY : (Low)
911 - MAIN RAM PARITY / DRAM PARITY: (High)
912 - SRAM PARITY: (Low) / SHARED RAM PARITY
913 - SRAM PARITY : (High) / SHARED RAM PARITY
914 - SERVO RAM PARITY
915 - LADDER EDITING CASSETTE RAMPARITY
916 - LADDER EDITING CASSETTE RAMPARITY
920 - WATCHDOG ALARM SERVO ALARM (1/2 AXIS)
921 - SUB CPU WATCHDOG ALARM SERVO ALARM (3/4 AXIS)
922 - SERVO ALARM (5/6/7/8 AXIS)
924 - SERVO MODULE SETTING ERROR
930 - CPU INTERRUPT
940 - PC BOARD INSTALLATION ERROR
941 - MEMORY PC BOARD CONNECTIONERROR
945 - SERIAL SPINDLE COMMUNICATIONERROR
946 - SECOND SERIAL SPINDLE COMMUNICATIONERROR
950 - FUSE BLOWN ALARM
960 - SUB CPU ERROR / DC24V POWER OFF
998 - ROM PARITY
1000 - EXTERNAL ALARM
Back to top
View user's profile Send private message Send e-mail
Display posts from previous:   
Post new topic   Reply to topic    Manufacturing Information Solutions Forum Index -> Fanuc All times are GMT - 5 Hours
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum


Powered by phpBB © 2001, 2005 phpBB Group