Fanuc 0/00/0-mate Control Alarms
0 - PLEASE TURN OFF POWER
1 - TH PARITY ALARM
2 - TV PARITY ALARM
3 - TOO MANY DIGITS
4 - ADDRESS NOT FOUND
5 - NO DATA AFTER ADDRESS
6 - ILLEGAL USE OF NEGATIVE SIGN
7 - ILLEGAL USE OF DECIMAL POINT
8 - ILLEGAL USE OF PROGRAM END
9 - ILLEGAL ADDRESS INPUT
10 - IMPROPER G-CODE
11 - NO FEEDRATE COMMANDED/
14 - CAN NOT COMMAND G95 / ILLEGAL LEAD COMMAND
15 - TOO MANY AXES COMMANDED
20 - OVER TOLERANCE OF RADIUS
21 - ILLEGAL PLANE AXIS COMMANDED
22 - NO CIRCLE RADIUS
23 - ILLEGAL RADIUS COMMAND
25 - CANNOT COMMAND F0 IN G02/G03 (M series)
27 - NO AXES COMMANDED IN G43/G44 (M series)
28 - ILLEGAL PLANE SELECT
29 - ILLEGAL OFFSET VALUE
30 - ILLEGAL OFFSET NUMBER
31 - ILLEGAL P COMMAND IN G10
32 - ILLEGAL OFFSET VALUE IN G10
33 - NO SOLUTION AT CRC
34 - NO CIRC ALLOWED IN ST-UP /EXT
35 - CAN NOT COMMANDED G39 / G31
36 - CAN NOT COMMANDED G31
37 - CAN NOT CHANGE PLANE IN CRC / CAN NOT CHANGE PLANE IN NRC
38 - INTERFERENCE IN CIRCULAR BLOCK
39 - CHF/CNR NOT ALLOWED IN NRC
40 - INTERFERENCE IN G90/G94 BLOCK
41 - INTERFERENCE IN CRC /NRC
42 - G45/G48 NOT ALLOWED IN CRC
43 - ILLEGAL T-CODE COMMAND
44 - G27-G30 NOT ALLOWED IN FIXED CYC
45 - ADDRESS Q NOT FOUND (G73/G83)
46 - ILLEGAL REFERENCE RETURN COMMAND
47 - ILLEGAL AXIS SELECT
48 - BASIC 3 AXIS NOT FOUND
49 - ILLEGAL OPERATION (G68/G69)(M series)
50 - CHF/CNR NOT ALLOWED IN THRD
51 - MISSING MOVE AFTER CHF/CNR
52 - CODE IS NOT G01 AFTER CHF/CNR
53 - TOO MANY ADDRESS COMMANDS
54 - NO TAPER ALLOWED AFTER CHF/ CNR (T series)
55 - MISSING MOVE VALUE IN CHF/CNR
56 - NO END POINT & ANGLE IN CHF/CNR
57 - NO SOLUTION OF BLOCK END
58 - END POINT NOT FOUND
59 - PROGRAM NUMBER NOT FOUND
60 - SEQUENCE NUMBER NOT FOUND
61 - ADDRESS P/Q NOT FOUND IN G70-G73 (T series)
62 - ILLEGAL COMMAND IN G71-G76 (T series)
63 - SEQUENCE NUMBER NOT FOUND
64 - SHAPE PROGRAM NOT MONOTONOUSLY
65 - ILLEGAL COMMAND IN G71-G73 (T series)
66 - IMPROPER G-CODE IN G71-G73
67 - CAN NOT ERROR IN MDI MODE
69 - FORMAT ERROR IN G70-G73
70 - NO PROGRAM SPACE IN MEMORY
71 - DATA NOT FOUND
72 - TOO MANY PROGRAMS
73 - PROGRAM NUMBER ALREADY IN USE
74 - ILLEGAL PROGRAM NUMBER
75 - PROTECT
76 - ADDRESS P NOT DEFINED
77 - SUB PROGRAM NESTING ERROR
78 - NUMBER NOT FOUND
79 - PROGRAM VERIFY ERROR
80 - G37ARRIVALSIGNALNOT ASSERTED
81 - OFFSET NUMBER NOT FOUND IN G37
82 - H-CODE NOT ALLOWED IN G37 / T-CODE NOT ALLOWED IN G37
83 - ILLEGAL AXIS COMMAND IN G37
85 - COMMUNICATION ERROR
86 - DR SIGNAL OFF
87 - BUFFER OVERFLOW
90 - REFERENCE RETURN INCOMPLETE
91 - REFERENCE RETURN INCOMPLETE or MANUAL RETURN TO THE REFERENCEPOSITION IS IMPOSSIBLEBECAUSE OF A TEMPORARYSTOP.
92 - AXES NOT ON THE REFERENCE POINT
94 - P TYPE NOT ALLOWED (COORD CHG)
95 - P TYPE NOT ALLOWED (EXT OFS CHG)
96 - P TYPE NOT ALLOWED (WRK OFS CHG)
97 - P TYPE NOT ALLOWED (AUTO EXEC)
98 - G28 FOUND IN SEQUENCE RETURN
99 - MDI EXEC NOT ALLOWED AFT. SEARCH
100 - PARAMETER WRITE ENABLE
101 - PLEASE CLEAR MEMORY
110 - DATA OVERFLOW
111 - CALCULATED DATA OVERFLOW
112 - DIVIDED BY ZERO
113 - IMPROPER COMMAND
114 - FORMAT ERROR IN MACRO
115 - ILLEGAL VARIABLE NUMBER
116 - WRITE PROTECTED VARIABLE
118 - PARENTHESIS NESTING ERROR
119 - ILLEGAL ARGUMENT
122 - FOUR FOLD MACRO MODAL-CALL or DUPLICATE MACRO MODAL-CALL
123 - CAN NOT USE MACRO COMMAND IN DNC
124 - MISSING END STATEMENT
125 - FORMAT ERROR IN MACRO
126 - ILLEGAL LOOP NUMBER
127 - NC, MACRO STATEMENT IN SAME BLOCK
128 - ILLEGAL MACRO SEQUENCE NUMBER
129 - ILLEGAL ARGUMENT ADDRESS
130 - ILLEGAL AXIS OPERATION
131 - TOO MANY EXTERNAL ALARM MESSAGES
132 - ALARM NUMBER NOT FOUND
133 - ILLEGAL DATA IN EXT. ALARM MSG
135 - ILLEGAL ANGLE COMMAND / SPINDLE ORIENTATION PLEASE
136 - ILLEGAL AXIS COMMAND / C/H-CODE IN SAME BLK.
137 - M-CODE & MOVE CMD IN SAME BLK.
139 - CAN NOT CHANGE PMC CONTROL AXIS
140 - BP/S alarm
141 - CAN NOT COMMAND G51 IN CRC
142 - ILLEGAL SCALE RATE
144 - ILLEGAL PLANE SELECTED
146 - IMPROPER G CODE
148 - ILLEGAL SETTING DATA
150 - ILLEGAL TOOL GROUP NUMBER
151 - TOOL GROUP NUMBER NOT FOUND
152 - NO SPACE FOR TOOL ENTRY
153 - T-CODE NOT FOUND
154 - NOT USING TOOL IN LIFE GROUP
155 - ILLEGAL T-CODE IN M06
156 - P/L COMMAND NOT FOUND
157 - TOO MANY TOOL GROUPS
158 - ILLEGAL TOOL LIFE DATA
159 - TOOL DATA SETTING INCOMPLETE
160 - MISMATCH WAITING M-CODE / G72.1 NESTING ERROR
161 - G72.1 NESTING ERROR
163 - COMMAND G68/G69 INDEPENDENTLY T series (At two-path)
169 - ILLEGAL TOOL GEOMETRY DATA
175 - ILLEGAL G107 COMMAND
176 - IMPROPER G CODE IN G107
177 - CHECK SUM ERROR (G05 MODE)
178 - G05 COMMANDED IN G41/G42 MODE
179 - PARAM. (NO. 7510) SETTING ERROR
180 - COMMUNICATION ERROR (REMOTE BUF)
181 - FORMAT ERROR IN G81 BLOCK (Hobbing machine, EGB) (M series)
182 - G81 NOT COMMANDED
183 - DUPLICATE G83
184 - ILLEGAL COMMAND IN G81
185 - RETURN TO REFERENCE POINT
186 - PARAMETER SETTING ERROR
190 - ILLEGAL AXIS SELECT
194 - SPINDLE COMMAND IN SYNCHRO-MODE
195 - SPINDLE CONTROL MODESWITCH
197 - C-AXIS COMMANDED IN SPINDLE MODE
199 - MACRO WORD UNDEFINED
200 - ILLEGAL S CODE COMMAND
201 - FEEDRATE NOT FOUND IN RIGID TAP
202 - POSITION LSI OVERFLOW
203 - PROGRAM MISS AT RIGID TAPPING
204 - ILLEGAL AXIS OPERATION
205 - RIGID MODE DI SIGNAL OFF
206 - CAN NOT CHANGE PLANE
207 - RIGID DATA MISMATCH
210 - CAN NOT COMMAND M198/M199
211 - G31 (HIGH) NOT ALLOWED IN G99 or CAN NOT COMMAND HIGH-SPEEDSKIP
212 - ILLEGAL PLANE SELECT
213 - ILLEGAL COMMAND IN SYNCHRO-MODE
214 - ILLEGAL COMMAND IN SYNCHRO-MODE
217 - DUPLICATE G51.2 (COMMANDS)
218 - NOT FOUND P/Q COMMAND IN G251
219 - COMMAND G250/G251 INDEPENDENTLY
220 - ILLEGAL COMMAND IN SYNCHR-MODE
221 - ILLEGAL COMMAND IN SYNCHR-MODE
222 - DNC OP. NOT ALLOWED IN BG.-EDIT
224 - RETURN TO REFERENCE POINT
225 - SYNCHRONOUS/MIXED CONTROL ERROR T series
226 - ILLEGAL COMMAND IN SYNCHRO-MODE T series
229 - CAN NOT KEEP SYNCHRO-STATE
230 - R CODE NOT FOUND
231 - ILLEGAL FORMAT IN G10 OR L50
232 - TOO MANY HELICAL AXIS COMMANDS
233 - DEVICE BUSY or P/S ALARM
239 - BP/S ALARM
240 - BP/S ALARM
241 - ILLEGAL FORMAT IN G02.2/G03.2
242 - ILLEGAL COMMAND IN G02.2/G03.2
243 - OVER TOLERANCE OF END POINT
244 - P/S ALARM
245 - T-CODE NOT ALLOWED IN THIS BLOCK
246 - No message
247 - No message
250 - Z AXIS WRONG COMMAND (ATC) / SIMULTANEOUS M06 AND Z-AXISMOVEMENT NOT ALLOWED
251 - ATC ERROR
252 - ATC SPINDLE ALARM
253 - G05 IS NOT AVAILABLE
300 - n-axis origin return
301 - APC alarm: nth-axis communication
302 - APC alarm: nth-axis over time
303 - APC alarm: nth-axis framing
304 - APC alarm: nth-axis parity
305 - APC alarm: nth-axis pulse error
306 - APC alarm: nth-axis battery voltage 0
307 - APC alarm: nth-axis battery low 1
308 - APC alarm: nth-axis battery low 2
309 - APC ALARM: n AXIS ZRN IMPOSSIBL
310/320/330/340/350/360/370/380 - n-axis origin return
311/321/331/341/351/361/371/381 - APC alarm: nth-axis communication
312/322/332/342/352/362/372/382 - APC alarm: nth-axis over time
313/323/333/343/353/363/373/383 - APC alarm: nth-axis framing
314/324/334/344/354/364/374/384 - APC alarm: nth-axis parity
315/325/335/345/355/365/375/385 - APC alarm: nth-axis pulse error
316/326/336/346/356/366/376/386 - APC alarm: nth-axis battery voltage 0
317/327/337/347/357/367/377/387 - APC alarm: nth-axis battery low 1
318/328/338/348/358/368/378/388 - APC alarm: nth-axis battery low 2
319/329/339/349/359/369/379/389 - SPC ALARM: n AXIS PULSE CODER
400 - SERVO ALARM: 1, 2TH AXIS OVERLOAD
401 - SERVO ALARM: 1, 2TH AXIS VRDY OFF
402 - SERVO ALARM: 3, 4TH AXIS OVERLOAD
403 - SERVO ALARM: 3, 4TH AXIS VRDY OFF
404 - SERVO ALARM: n-th AXIS VRDY ON
405 - SERVO ALARM: ZERO POINT RETURN FAULT
406 - SERVO ALARM: 7, 8TH AXIS OVER LOAD or 7, 8TH AXIS VRDY OFF
409 - SPINDLE ALARM DETECTION
410,420,430,440,450,460,470 - SERVO ALARM: n-th AXIS - EXCESS ERROR
411,421,431,441,451,461,471 - SERVO ALARM: n-th AXIS - EXCESS ERROR
413,423,433,443,453,463,473 - SERVO ALARM: n-th AXIS - LSI OVERFLOW
414,424,434,444,454,464,474 - SERVO ALARM: n-th AXIS - DETECTION RELATED ERROR
415,425,435,445,455,465,475 - SERVO ALARM: n-th AXIS - EXCESS SHIFT
416,426,436,446,456,466,476 - SERVO ALARM: n-th AXIS - DISCONNECTION
417,427,437,447,457,467,477 - SERVO ALARM: n-th AXIS - PARAMETER INCORRECT
490 - SERVO ALARM: 5TH AXIS OVER LOAD
491 - SERVO ALARM: 5, 6TH VRDY OFF
494 - SERVO ALARM: 5, 6TH AXIS VRDY ON
495 - SERVO ALARM: 5, 6TH AXIS ZEROPOINT RETURN
408 - SPINDLE SERIAL LINK STARTFAULT
5n0 - OVER TRAVEL : +n
5n1 - OVER TRAVEL : -n
5n2 - OVER TRAVEL : +n
5n3 - OVER TRAVEL : -n
5n4 - OVER TRAVEL : +n
5n5 - OVER TRAVEL : -n
5n4 - OVER TRAVEL : +n
5n5 - OVER TRAVEL : -n
520 - OVER TRAVEL : +Z
590 - Tool post interference alarm:+X-axis
591 - Tool post interference alarm:-X-axis
592 - Tool post interference alarm:+Z-axis
593 - Tool post interference alarm:-Z-axis
500-599 - Macro alarms
600 - PMC ALARM : INVALID INSTRUCTION
601 - PMC ALARM : RAM PARITY
602 - PMC ALARM : SERIAL TRANSFER
603 - PMC ALARM : WATCHDOG
604 - PMC ALARM : ROM PARITY
605 - PMC ALARM : OVER STEP
606 - PMC ALARM : I/O MODULE ASSIGNMENT
607 - PMC ALARM : I/O LINK
700 - OVERHEAT: CONTROL UNIT
704 - OVERHEAT: SPINDLE
899 - M-NET INTERFACE ALARM
910 - MAIN RAM PARITY / DRAM PARITY : (Low)
911 - MAIN RAM PARITY / DRAM PARITY: (High)
912 - SRAM PARITY: (Low) / SHARED RAM PARITY
913 - SRAM PARITY : (High) / SHARED RAM PARITY
914 - SERVO RAM PARITY
915 - LADDER EDITING CASSETTE RAMPARITY
916 - LADDER EDITING CASSETTE RAMPARITY
920 - WATCHDOG ALARM SERVO ALARM (1/2 AXIS)
921 - SUB CPU WATCHDOG ALARM SERVO ALARM (3/4 AXIS)
922 - SERVO ALARM (5/6/7/8 AXIS)
924 - SERVO MODULE SETTING ERROR
930 - CPU INTERRUPT
940 - PC BOARD INSTALLATION ERROR
941 - MEMORY PC BOARD CONNECTIONERROR
945 - SERIAL SPINDLE COMMUNICATIONERROR
946 - SECOND SERIAL SPINDLE COMMUNICATIONERROR
950 - FUSE BLOWN ALARM
960 - SUB CPU ERROR / DC24V POWER OFF
998 - ROM PARITY
1000 - EXTERNAL ALARM |
|