DNC / file transfer settings for Okuma OSP7000

 
Post new topic   Reply to topic    Manufacturing Information Solutions Forum Index -> Okuma
View previous topic :: View next topic  
Author Message
mistux
Site Admin


Joined: 25 Jun 2004
Posts: 1042
Location: South Bend, Indiana USA

PostPosted: Thu Sep 11, 2008 1:11 pm    Post subject: DNC / file transfer settings for Okuma OSP7000 Reply with quote

Set the following parameters on the machine:

Optional Parameter (bit) Value
#1 00011011
#8 10101010
#12 10100010



Optional Parameter (word) Value
#1 0
#39 9600
#54 1

To set the CNC up for drip feed:
Drip feed on this control is an optional extra, see the Okuma manual for instructions.


--------------------------------------------------------------------------------

Set ConnectCNC as follows:

Common Settings
Name Okuma 7000
Baudrate 9600
Data bits 7
Stop bits 2
Parity Even
Flow control Xon/Xoff
Xon Char. 17
Xoff char. 19
Port as available

Each file should begin with "$filename.MIN%" (without the quotes), and end with "%". I think the first character after the $ has to be a letter not a number.
Back to top
View user's profile Send private message Send e-mail
Display posts from previous:   
Post new topic   Reply to topic    Manufacturing Information Solutions Forum Index -> Okuma All times are GMT - 5 Hours
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum


Powered by phpBB © 2001, 2005 phpBB Group